Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
The Journal of Advanced Prosthodontics ; : 89-99, 2021.
Article in English | WPRIM | ID: wpr-895761

ABSTRACT

PURPOSE@#This study aimed to compare the accuracy (trueness and precision) of interim crowns fabricated using DLP (digital light processing) according to postcuring time. MATERIALS AND METHODS: A virtual stone study die of the upper right first molar was created using a dental laboratory scanner. After designing interim crowns on the virtual study die and saving them as Standard Triangulated Language files, 30 interim crowns were fabricated using a DLP-type 3D printer. Additively manufactured interim crowns were post-cured using three different time conditions-10-minute post-curing interim crown (10-MPCI), 20-minute postcuring interim crown (20-MPCI), and 30-minute post-curing interim crown (30-MPCI) (n = 10 per group). The scan data of the external and intaglio surfaces were overlapped with reference crown data, and trueness was measured using the best-fit alignment method. In the external and intaglio surface groups (n = 45 per group), precision was measured using a combination formula exclusive to scan data (10 C2). Significant differences in accuracy (trueness and precision) data were analyzed using the Kruskal-Wallis H test, and post hoc analysis was performed using the Mann-Whitney U test with Bonferroni correction (α=.05). @*RESULTS@#In the 10-MPCI, 20-MPCI, and 30-MPCI groups, there was a statistically significant difference in the accuracy of the external and intaglio surfaces (P <.05). On the external and intaglio surfaces, the root mean square (RMS) values of trueness and precision were the lowest in the 10-MPCI group. @*CONCLUSION@#Interim crowns with 10-minute post-curing showed high accuracy.

2.
The Journal of Advanced Prosthodontics ; : 89-99, 2021.
Article in English | WPRIM | ID: wpr-903465

ABSTRACT

PURPOSE@#This study aimed to compare the accuracy (trueness and precision) of interim crowns fabricated using DLP (digital light processing) according to postcuring time. MATERIALS AND METHODS: A virtual stone study die of the upper right first molar was created using a dental laboratory scanner. After designing interim crowns on the virtual study die and saving them as Standard Triangulated Language files, 30 interim crowns were fabricated using a DLP-type 3D printer. Additively manufactured interim crowns were post-cured using three different time conditions-10-minute post-curing interim crown (10-MPCI), 20-minute postcuring interim crown (20-MPCI), and 30-minute post-curing interim crown (30-MPCI) (n = 10 per group). The scan data of the external and intaglio surfaces were overlapped with reference crown data, and trueness was measured using the best-fit alignment method. In the external and intaglio surface groups (n = 45 per group), precision was measured using a combination formula exclusive to scan data (10 C2). Significant differences in accuracy (trueness and precision) data were analyzed using the Kruskal-Wallis H test, and post hoc analysis was performed using the Mann-Whitney U test with Bonferroni correction (α=.05). @*RESULTS@#In the 10-MPCI, 20-MPCI, and 30-MPCI groups, there was a statistically significant difference in the accuracy of the external and intaglio surfaces (P <.05). On the external and intaglio surfaces, the root mean square (RMS) values of trueness and precision were the lowest in the 10-MPCI group. @*CONCLUSION@#Interim crowns with 10-minute post-curing showed high accuracy.

3.
The Journal of Advanced Prosthodontics ; : 24-35, 2021.
Article in English | WPRIM | ID: wpr-875383

ABSTRACT

PURPOSE@#This study was to evaluate the effect of rinsing time on the accuracy of interim crowns fabricated by digital light processing. @*MATERIALS AND METHODS@#The maxillary right first molar master die was duplicated using a silicone material, while a study die was produced using epoxy resin. Scans of the epoxy resin die were used in combination with CAD software to design a maxillary right first molar interim crown. Based on this design, 24 interim crowns were fabricated with digital light processing. This study examined the trueness and precision of products that were processed with one of the three different postprocessing rinsing times (1 min, 5 min, and 10 min). Trueness was measured by superimposing reference data with scanned data from external, intaglio, and marginal surfaces. Precision was measured by superimposing the scan data within the group. The trueness and precision data were analyzed using KruskalWallis, nonparametric, and post-hoc tests, and were compared using a MannWhitney U test with Bonferroni correction (α=.05). @*RESULTS@#The trueness of the external and intaglio surfaces of crowns varied significantly among the different rinsing times (P=.004, P=.003), but there was no statistically significant difference in terms of trueness measurements of the marginal surfaces (P=.605). In terms of precision, statistically significant differences were found among the external, intaglio, and marginal surfaces (P=.001). @*CONCLUSION@# Interim crowns rinsed for 10 minutes showed high accuracy.

SELECTION OF CITATIONS
SEARCH DETAIL